Contactors and Relays Control relay easy, Multi Function Display MFD-Titan® |
| |
| Stairway lighting |
For a conventional circuit a minimum of five elements
are required. An impulse relay, two timing relays, two auxiliary relays.
easy needs only four elements. With five connections and the easy
circuit the stairway lighting is operational.
|
 |
Important note
Four such stairway circuits can be implemented with one easy device.

| Button pressed briefly |
Light On or Off, the impulse changeover relay function
is able to switch off continuous lighting where required.
|
| Light Off after 6 min. |
Switched off automatically. With continuous lighting
this function is not active. |
| Button pressed for longer than 5 s |
Continuous lighting |
|
| |
The easy circuit configuration for the function below
looks like this:

Expanded easy circuit configuration: after four hours, the continuous
lighting is switched off.
 |
| |
Meaning of the contacts and relays used:
 |